The Madimack InverELITE V4 (also sold as the Elite V4) is a full inverter pool heat pump for heating and cooling, in sizes from 10kW to 42kW, with a twin rotary Mitsubishi DC compressor, a rated COP of up to 22, R32 refrigerant, 40mm water connections and sound levels from 36 dB(A) at one metre.
This is Madimack's top residential range. People choose it for two reasons: it is very quiet, and it is very cheap to run for the heat it puts out. If the heater has to sit near a bedroom window, an entertaining area or the neighbour's fence, this is the one to look at first.
Why it is so quiet
The cabinet is wrapped in three layers of sound insulation: condensed fibre, foam and a metal jacket. At half load, where an inverter spends most of its time once the pool is warm, Madimack measures 36.4 dB(A) at one metre on the 10kW and 43.6 dB(A) on the largest unit. At ten metres every size is under 30 dB(A).
3D airflow: easier to find a spot for it
Most heat pumps pull air in at the back and blow it out the front, so they need a long clear run in front. The V4 draws air in at the back and sends it out in three directions. Madimack says this cuts the ventilation space it needs and makes it simpler to install.
Twin rotary compressor and centrifugal fan
Inside is a twin rotary Mitsubishi DC inverter compressor paired with a commercial grade centrifugal fan. The compressor runs anywhere from about 20% to 100% of its capacity, so it works hard to bring a cold pool up to temperature, then drops back and sips power to hold it there.
What COP 22 means for your power bill
COP is heat out divided by electricity in. Madimack rates the 23kW model at a COP of up to 22 at 27°C air and 27°C water, which is 22kW of heat for each 1kW of power when it is running slowly in warm weather. On a cool 15°C day the same unit is rated at 9.6 down to 5.6. The 2027 model 15kW is rated up to 24.
Video: Madimack explains how its inverter pool heat pumps work.
What you get
Heating and cooling. Heating from 18°C to 40°C, cooling from 5°C to 30°C, or auto mode to hold a set point.
Three power levels. High, Medium and a Low mode suited to running overnight.
Works in the cold. Rated to operate in air temperatures from -20°C to 43°C.
WiFi control. Pair it with the Madimack app from the touch screen.
Quick Connect. External plugs on the cabinet for connecting pumps and controllers without opening the unit up.
Built for the coast. Marine grade aluminium alloy casing.
Plug in sizes. The 10kW, 12kW, 14kW and 15kW run from a standard 10A outlet.
Compare the sizes
Model
Heating at 27°C air
Heating at 15°C air
Cooling
COP at 27°C
Max current
Breaker
Power connection
Sound at 1m, 50% load
Advised water flow
10kW
9.8 kW
6.8 kW
4.8 kW
19.5 to 7.0
9 A
15 A
10A plug
36.4 dB(A)
50 L/min
12kW
11.8 kW
8.1 kW
5.5 kW
19.7 to 7.2
10 A
15 A
10A plug
36.5 dB(A)
65 L/min
14kW
14.2 kW
9.6 kW
6.7 kW
20.2 to 7.2
10 A
15 A
10A plug
38.4 dB(A)
70 L/min
15kW (2027 model)
15.0 kW
9.8 kW
6.7 kW
24 to 8.7
10 A
15 A
10A plug
38.4 dB(A)
59 L/min
17kW
17.0 kW
11.5 kW
9.4 kW
20.4 to 7.2
16 A
20 A
Hardwired
40.3 dB(A)
85 L/min
19kW
19.0 kW
13.0 kW
10.8 kW
20.0 to 7.0
16.5 A
20 A
Hardwired
40.5 dB(A)
100 L/min
23kW
23.0 kW
15.0 kW
11.9 kW
22.0 to 7.3
18.5 A
25 A
Hardwired
41.0 dB(A)
135 L/min
27kW
27.0 kW
18.5 kW
13.5 kW
21.0 to 7.2
20.5 A
25 A
Hardwired
41.2 dB(A)
140 L/min
28kW (2027 model)
28.0 kW
19.3 kW
13.5 kW
20 to 8.0
20.5 A
25 A
Hardwired
41.2 dB(A)
150 L/min
33kW
33.0 kW
22.7 kW
15.4 kW
20.3 to 7.1
24 A
30 A
Hardwired
43.0 dB(A)
180 L/min
34kW (2027 model)
34.0 kW
23.5 kW
15.4 kW
20 to 7.8
24 A
30 A
Hardwired
43.0 dB(A)
183 L/min
40kW (three phase)
40.8 kW
29.0 kW
20.0 kW
18.9 to 7.0
12.5 A
15 A
Hardwired, 400V 3 phase
43.6 dB(A)
220 L/min
42kW (2027 model, three phase)
42.0 kW
30.0 kW
20.0 kW
18.9 to 7.8
12.5 A
15 A
Hardwired, 400V 3 phase
43.6 dB(A)
250 L/min
Heating figures are at 27°C water and 80% humidity (27°C air) and 26°C water and 70% humidity (15°C air). Cooling is at 35°C air and 28°C water. Water flow is plus or minus 20%. Figures are Madimack's published data; the nameplate on the unit is the final reference.
Size guide
Which size suits my pool?
It depends on your pool volume, your climate, how long a season you want, wind and shade, and whether you use a cover. Madimack's pool heat pump calculator gives a size for your pool in a couple of minutes.
Video: Madimack on choosing the right size heat pump with its calculator.
1x Madimack InverELITE V4 heat pump in the size selected
4x Rubber feet
1x Water union
1x Condensate drainage nozzle
1x User manual
📐 Measurements
Measurements are approximate.
10kW, 12kW, 14kW and 15kW: 936 x 494 x 655 mm (L x W x H), 83 kg
17kW: 1036 x 494 x 655 mm (L x W x H), 90 kg
19kW: 1036 x 494 x 655 mm (L x W x H), 94 kg
23kW: 1104 x 494 x 757 mm (L x W x H), 100 kg
27kW and 28kW: 1129 x 504 x 945 mm (L x W x H), 125 kg
33kW and 34kW: 1310 x 514 x 945 mm (L x W x H), 154 kg
40kW and 42kW: 1405 x 514 x 1070 mm (L x W x H), 186 kg
Water connection: 40 mm
⚙️ Specifications & Compatibility
Brand: Madimack
Range: InverELITE V4 (Elite V4)
Type: Full inverter electric pool heat pump, heating and cooling
Power supply: 230V single phase (10kW to 34kW), 400V three phase (40kW and 42kW)
Compressor: Twin rotary Mitsubishi DC inverter
Fan: Commercial grade centrifugal
Heat exchanger: Titanium
Refrigerant: R32
Casing: Marine grade aluminium alloy
Set point range: 5°C to 40°C
Operating air temperature: -20°C to 43°C
Residual current device: 30 mA required on all models
SKU (10kW): HPELV4AU100
SKU (12kW): HPELV4AU120
SKU (14kW): HPELV4AU140
SKU (15kW 2027 model): HPELV4AU150-A
SKU (17kW): HPELV4AU170
SKU (19kW): HPELV4AU190
SKU (23kW): HPELV4AU230
SKU (27kW): HPELV4AU270
SKU (28kW 2027 model): HPELV4AU280-A
SKU (33kW): HPELV4AU330
SKU (34kW 2027 model): MKL-15-91046
SKU (40kW): HPELV4AU410
SKU (42kW 2027 model): MKL-15-91047
*Images are for illustration purposes only. The actual product may differ from the image. Please read the product description and included parts for full details.
💡 Before You Buy
Check your power supply. The 10kW, 12kW, 14kW and 15kW plug into a 10A outlet. The 17kW and larger must be hardwired on their own circuit by a licensed electrician, and the 40kW and 42kW need 400V three phase power. Every size needs a 30 mA safety switch on the circuit.
Check where it will sit. It must be outdoors in the open air. Madimack does not allow it indoors, in a shed, under a deck or under the house. Keep 1 metre clear above it and nothing within 150 mm of the back, where the air goes in.
Check your water flow. The heat pump relies on your filtration pump. Compare the advised water flow in the table above with what your pump delivers. Do not reduce the 40 mm pipework, and keep the pipe run to the pool under 10 metres where you can.
2027 model or current model? The 15kW, 28kW, 34kW and 42kW are Madimack's upgraded 2027 versions of the 14kW, 27kW, 33kW and 40kW. They use the same cabinet sizes, so either will fit the same space.
Plan for a pool cover. A cover holds the heat in overnight, which shortens run times and can mean a smaller unit does the job.
🔧 Our Tips
Pump first, heater second. Madimack's start-up order is to run the filtration pump, set your temperature, then switch the heater on. The fan runs for about a minute before the compressor starts. When shutting down, stop the heat pump before the pump.
Use the temperature difference to set your flow. Aim for the water leaving the heater to be about 2°C to 3°C warmer than the water going in. If the gap is much bigger, it needs more flow.
An E3 or E6 code usually means low flow. Check the pump is running, the valves are open and the filter and skimmer baskets are clean.
Keep the water balanced. Madimack asks for pH 7.2 to 7.8, total alkalinity 80 to 120 ppm (100 to 150 ppm for vinyl pools) and calcium hardness 200 to 400 ppm.
Book a yearly service. Madimack recommends a service by a licensed technician every 12 months. Keep the invoice with your proof of purchase.
❓ Common Questions
How quiet is it? At half load Madimack measures 36.4 to 43.6 dB(A) at one metre depending on size, and under 30 dB(A) at ten metres for every size.
Can it cool the pool as well? Yes. Cooling mode works from 5°C to 30°C.
Which sizes plug into a normal power point? The 10kW, 12kW, 14kW and 15kW use a 10A plug. Everything larger is hardwired.
Is there a three phase model? Yes, the 40kW and the 2027 model 42kW run on 400V three phase.
What is different about the 2027 models? Madimack describes them as upgraded versions of the V4 with higher rated output and efficiency in the same cabinets. The 15kW is rated at a COP of up to 24.
Covered by the Madimack manufacturer warranty: 25 years on the titanium heat exchanger, 15 years on the compressor, 7 years on all parts and 1 year on-site labour. The warranty starts on the purchase date and applies to the original purchaser at the original installation address. Keep your proof of purchase.